SYSTEM.INITIALIZE: BLUEPRINT_UNFOLD
DWG TITLEPORTFOLIO BLUEPRINT
DRAWN BYDINESH KUMAR
SCALE1:1
REVISIONA.02
Back to Simulators
Thermal Engineering

Injection Molding Cooling Simulator

Analyze 1D transient heat conduction through polymer thickness. Simulate the temperature decay at the part center, predict ejection readiness, and explore the effect of polymer thermal properties.

Model
Transient 1D Heat
Analytic Fourier Series
Material Preset
PP
Standard Preset
Output
CSV
Export ready

Process & Material Parameters

Material Preset
Transient Cooling Playback

Transient Heat Model

Cooling Time (t_cool)
t_cool = (s^2 / (pi^2 * alpha)) * ln((4/pi) * (Tm - Tw) / (Te - Tw))
Thermal Diffusivity (alpha)
alpha = k / (rho * Cp)
Dimensionless Fourier Number (Fo)
Fo = (alpha * t) / (s/2)^2

The 1D Fourier series model calculates temperature evolution under transient heat conduction.

For the current configuration, ejection readiness occurs at t = 16.39 seconds when the core temperature cooling curve crosses below Te (90°C).

Assumes the mold cavity walls remain at a constant mold temperature (Tw).

Molded Part & Core/Cavity Plates

H₂OH₂OCore PlateH₂OH₂OCavity PlateCOOLING TIME: 16.4sT_center: 230°C3.0mmMOLD CLOSED
Estimated Cooling Time
16.39s
Thermal Diffusivity
0.0877mm²/s
Active Center Temp
230.0°C
Fourier Number (Fo)
0.639

Part Center Temperature Profile

Cooling Log Data

Time Elapsed (s)Center Temp (°C)
0.00230.0
2.08225.0
4.17199.8
6.25172.2
8.33148.5
10.42128.8
12.50112.7
14.5899.5
16.6788.7
18.7579.8
20.8372.6
22.9266.7
25.0061.8